The modes of operation are set by the dimensions of the pressure field
to which this boundary condition is applied, the \c psi entry and the value
of \c gamma:
\table
Mode | dimensions | psi | gamma
incompressible subsonic | p/rho | |
compressible subsonic | p | none |
compressible transonic | p | psi | 1
compressible supersonic | p | psi | > 1
\endtable
For most applications the totalPressure boundary condition now only
requires p0 to be specified e.g.
outlet
{
type totalPressure;
p0 uniform 1e5;
}
Added the option '-subDict' to specify a sub-dictionary if multiple
replacement sets are present in the same file. This also provides
backward compatibility by setting '-subDict dictionaryReplacement'
The use of the term 'source' in the context of post-processing is
confusing and does not properly describe the process of region
selection. The new names 'surfaceRegion' and 'volRegion' better
describe the purpose of the functionObjects which is to provide field
processing functionality limited to a specified region of space, either
a surface or volume.
The keyword 'source' is renamed 'regionType' which better describes the
purpose which is to specify the method by which the surface or volume
region is selected.
The keyword to select the name of the surface or volume region is
renamed from 'sourceName' to 'name' consistent with the other
name-changes above.
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry. Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':
Property | Description | Required | Default value
U | velocity field name | no | U
phi | flux field name | no | phi
.
.
.
However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.
Property | Description | Required | Default value
pName | pressure field name | no | p
UName | velocity field name | no | U
This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance. In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
This changes simplifies the specification of functionObjects in
controlDict and is consistent with the 'libs' option in controlDict to
load special solver libraries.
Support for the old 'functionObjectLibs' name is supported for backward compatibility.
for consistency with the time controls in controlDict and to avoid
unnecessary confusion. All code and tutorials have been updated.
The old names 'outputControl' and 'outputInterval' are but supported for
backward compatibility but deprecated.
See http://www.openfoam.org/mantisbt/view.php?id=2076
- .org is the file extension for emacs org-mode as well
- .orig is more to the point (.org isn't always recognized as "original")
- .original is too long, although more consistent with the convention
of source code file naming
Update script contributed by Bruno Santos
in decomposeParDict.
This default number of processors may be overridden by the new "-np"
option to runParallel which must be specified before the application
name e.g.:
runParallel -np 4 pisoFoam
The built-in explicit symplectic integrator has been replaced by a
general framework supporting run-time selectable integrators. Currently
the explicit symplectic, implicit Crank-Nicolson and implicit Newmark
methods are provided, all of which are 2nd-order in time:
Symplectic 2nd-order explicit time-integrator for 6DoF solid-body motion:
Reference:
Dullweber, A., Leimkuhler, B., & McLachlan, R. (1997).
Symplectic splitting methods for rigid body molecular dynamics.
The Journal of chemical physics, 107(15), 5840-5851.
Can only be used for explicit integration of the motion of the body,
i.e. may only be called once per time-step, no outer-correctors may be
applied. For implicit integration with outer-correctors choose either
CrankNicolson or Newmark schemes.
Example specification in dynamicMeshDict:
solver
{
type symplectic;
}
Newmark 2nd-order time-integrator for 6DoF solid-body motion:
Reference:
Newmark, N. M. (1959).
A method of computation for structural dynamics.
Journal of the Engineering Mechanics Division, 85(3), 67-94.
Example specification in dynamicMeshDict:
solver
{
type Newmark;
gamma 0.5; // Velocity integration coefficient
beta 0.25; // Position integration coefficient
}
Crank-Nicolson 2nd-order time-integrator for 6DoF solid-body motion:
The off-centering coefficients for acceleration (velocity integration) and
velocity (position/orientation integration) may be specified but default
values of 0.5 for each are used if they are not specified. With the default
off-centering this scheme is equivalent to the Newmark scheme with default
coefficients.
Example specification in dynamicMeshDict:
solver
{
type CrankNicolson;
aoc 0.5; // Acceleration off-centering coefficient
voc 0.5; // Velocity off-centering coefficient
}
Both the Newmark and Crank-Nicolson are proving more robust and reliable
than the symplectic method for solving complex coupled problems and the
tutorial cases have been updated to utilize this.
In this new framework it would be straight forward to add other methods
should the need arise.
Henry G. Weller
CFD Direct
so that the specification of the name and dimensions are optional in property dictionaries.
Update tutorials so that the name of the dimensionedScalar property is
no longer duplicated but optional dimensions are still provided and are
checked on read.
LTS is selected by the ddt scheme e.g. in the
tutorials/multiphase/interFoam/ras/DTCHull case:
ddtSchemes
{
default localEuler rDeltaT;
}
LTSInterFoam is no longer needed now that interFoam includes LTS
support.
by introducing rational base-classes rather than using the hideous
'switch' statement. Further rationalization of the cell-selection
mechanism will be implemented via an appropriate class hierarchy to
replace the remaining 'switch' statement.
Mesh-motion is currently handled very inefficiently for cellSets and not
at all for inter-region coupling. The former will be improved when the
cell-selection classes are written and the latter by making the
meshToMesh class a MeshObject after it has been corrected for mapFields.
fvOptions does not have the appropriate structure to support MRF as it
is based on option selection by user-specified fields whereas MRF MUST
be applied to all velocity fields in the particular solver. A
consequence of the particular design choices in fvOptions made it
difficult to support MRF for multiphase and it is easier to support
frame-related and field related options separately.
Currently the MRF functionality provided supports only rotations but
the structure will be generalized to support other frame motions
including linear acceleration, SRF rotation and 6DoF which will be
run-time selectable.
Existing case did not properly converge and suffered slow convergence
with the water level failing to reach an equilibrium. A slight rise in
the channel appears to help the water level reach an equlibrium when the flow
rate over the rise matches the inlet flow rate.
For multi-region cases the default location of blockMeshDict is now system/<region name>
If the blockMeshDict is not found in system then the constant directory
is also checked providing backward-compatibility
The old separate incompressible and compressible libraries have been removed.
Most of the commonly used RANS and LES models have been upgraded to the
new framework but there are a few missing which will be added over the
next few days, in particular the realizable k-epsilon model. Some of
the less common incompressible RANS models have been introduced into the
new library instantiated for incompressible flow only. If they prove to
be generally useful they can be templated for compressible and
multiphase application.
The Spalart-Allmaras DDES and IDDES models have been thoroughly
debugged, removing serious errors concerning the use of S rather than
Omega.
The compressible instances of the models have been augmented by a simple
backward-compatible eddyDiffusivity model for thermal transport based on
alphat and alphaEff. This will be replaced with a separate run-time
selectable thermal transport model framework in a few weeks.
For simplicity and ease of maintenance and further development the
turbulent transport and wall modeling is based on nut/nuEff rather than
mut/muEff for compressible models so that all forms of turbulence models
can use the same wall-functions and other BCs.
All turbulence model selection made in the constant/turbulenceProperties
dictionary with RAS and LES as sub-dictionaries rather than in separate
files which added huge complexity for multiphase.
All tutorials have been updated so study the changes and update your own
cases by comparison with similar cases provided.
Sorry for the inconvenience in the break in backward-compatibility but
this update to the turbulence modeling is an essential step in the
future of OpenFOAM to allow more models to be added and maintained for a
wider range of cases and physics. Over the next weeks and months more
turbulence models will be added of single and multiphase flow, more
additional sub-models and further development and testing of existing
models. I hope this brings benefits to all OpenFOAM users.
Henry G. Weller
When using models which require the wallDist e.g. kOmegaSST it will
request the method to be used from the wallDist sub-dictionary in
fvSchemes e.g.
wallDist
{
method meshWave;
}
specifies the mesh-wave method as hard-coded in previous OpenFOAM versions.