- input or output scaling of values to manage dissimilar unit systems
in the structures model
- logging of communicated force, moments and updated positions.
This allows tracking of the information exchange throughout the
duration of the simulation and may assist in post-simulation diagnosis.
- controlled by the the 'printExecutionFormat' InfoSwitch in
etc/controlDict
// Style for "ExecutionTime = " output
// - 0 = seconds (with trailing 's')
// - 1 = day-hh:mm:ss
ExecutionTime = 112135.2 s ClockTime = 113017 s
ExecutionTime = 1-07:08:55.20 ClockTime = 1-07:23:37
- Callable via the new Time::printExecutionTime() method,
which also helps to reduce clutter in the applications.
Eg,
runTime.printExecutionTime(Info);
vs
Info<< "ExecutionTime = " << runTime.elapsedCpuTime() << " s"
<< " ClockTime = " << runTime.elapsedClockTime() << " s"
<< nl << endl;
--
ENH: return elapsedClockTime() and clockTimeIncrement as double
- previously returned as time_t, which is less portable.
Support the following expansions when they occur at the start of a
string:
Short-form Equivalent
========= ===========
<etc>/ ~OpenFOAM/ (as per foamEtcFile)
<case>/ $FOAM_CASE/
<constant>/ $FOAM_CASE/constant/
<system>/ $FOAM_CASE/system/
These can be used in fileName expansions to improve clarity and reduce
some typing
"<constant>/reactions" vs "$FOAM_CASE/constant/reactions"
These BCs blend between typical inflow and outflow conditions based on the
velocity orientation.
airFoil2D tutorial updated to demonstrate these new BCs.
Now pimpleDyMFoam is exactly equivalent to pimpleFoam when running on a
staticFvMesh. Also when the constant/dynamicMeshDict is not present a
staticFvMesh is automatically constructed so that the pimpleDyMFoam solver can
run any pimpleFoam case without change.
pimpleDyMFoam: Store Uf as an autoPtr for better error handling
pimpleFoam: Set initial deltaT from the Courant number
for improved stability on start-up and compatibility with pimpleDyMFoam
ENH: pimpleFoam: Merged dynamic mesh functionality of pimpleDyMFoam into pimpleFoam
and replaced pimpleDyMFoam with a script which reports this change.
The pimpleDyMFoam tutorials have been moved into the pimpleFoam directory.
This change is the first of a set of developments to merge dynamic mesh
functionality into the standard solvers to improve consistency, usability,
flexibility and maintainability of these solvers.
Henry G. Weller
CFD Direct Ltd.
tutorials/incompressible/pimpleFoam: Updated pimpleDyMFoam tutorials to run pimpleFoam
Renamed tutorials/incompressible/pimpleFoam/RAS/wingMotion/wingMotion2D_pimpleDyMFoam
-> tutorials/incompressible/pimpleFoam/RAS/wingMotion/wingMotion2D_pimpleFoam
Within decomposeParDict, it is now possible to specify a different
decomposition method, methods coefficients or number of subdomains
for each region individually.
The top-level numberOfSubdomains remains mandatory, since this
specifies the number of domains for the entire simulation.
The individual regions may use the same number or fewer domains.
Any optional method coefficients can be specified in a general
"coeffs" entry or a method-specific one, eg "metisCoeffs".
For multiLevel, only the method-specific "multiLevelCoeffs" dictionary
is used, and is also mandatory.
----
ENH: shortcut specification for multiLevel.
In addition to the longer dictionary form, it is also possible to
use a shorter notation for multiLevel decomposition when the same
decomposition method applies to each level.
- Instead of relying on #inputMode to effect a global change it is now
possible (and recommended) to a temporary change in the inputMode
for the following entry.
#default : provide default value if entry is not already defined
#overwrite : silently remove a previously existing entry
#warn : warn about duplicate entries
#error : error if any duplicate entries occur
#merge : merge sub-dictionaries when possible (the default mode)
This is generally less cumbersome than the switching the global
inputMode. For example to provide a set of fallback values.
#includeIfPresent "user-files"
...
#default value uniform 10;
vs.
#includeIfPresent "user-files"
#inputMode protect
...
value uniform 10;
#inputMode merge // _Assuming_ we actually had this before
These directives can also be used to suppress the normal dictionary
merge semantics:
#overwrite dict { entry val; ... }
Note: performs its own tracking and does not rely on the base
particle::trackXXX functions, and uses a local particle position.
Look to update to barycentric tracking in the future.
terms of the local barycentric coordinates of the current tetrahedron,
rather than the global coordinate system.
Barycentric tracking works on any mesh, irrespective of mesh quality.
Particles do not get "lost", and tracking does not require ad-hoc
"corrections" or "rescues" to function robustly, because the calculation
of particle-face intersections is unambiguous and reproducible, even at
small angles of incidence.
Each particle position is defined by topology (i.e. the decomposed tet
cell it is in) and geometry (i.e. where it is in the cell). No search
operations are needed on restart or reconstruct, unlike when particle
positions are stored in the global coordinate system.
The particle positions file now contains particles' local coordinates
and topology, rather than the global coordinates and cell. This change
to the output format is not backwards compatible. Existing cases with
Lagrangian data will not restart, but they will still run from time
zero without any modification. This change was necessary in order to
guarantee that the loaded particle is valid, and therefore
fundamentally prevent "loss" and "search-failure" type bugs (e.g.,
2517, 2442, 2286, 1836, 1461, 1341, 1097).
The tracking functions have also been converted to function in terms
of displacement, rather than end position. This helps remove floating
point error issues, particularly towards the end of a tracking step.
Wall bounded streamlines have been removed. The implementation proved
incompatible with the new tracking algorithm. ParaView has a surface
LIC plugin which provides equivalent, or better, functionality.
Additionally, bug report <https://bugs.openfoam.org/view.php?id=2517>
is resolved by this change.
- although this has been supported for many years, the tutorials
continued to use "convertToMeters" entry, which is specific to blockMesh.
The "scale" is more consistent with other dictionaries.
ENH:
- ignore "scale 0;" (treat as no scaling) for blockMeshDict,
consistent with use elsewhere.