to ensure 'patchType' is set as specified.
Required substantial change to the organization of the reading of the
'value' entry requiring careful testing and there may be some residual
issues remaining. Please report any problems with the reading and
initialization of patch fields.
Resolves bug-report http://bugs.openfoam.org/view.php?id=2266
to have the prefix 'write' rather than 'output'
So outputTime() -> writeTime()
but 'outputTime()' is still supported for backward-compatibility.
Also removed the redundant secondary-writing functionality from Time
which has been superseded by the 'writeRegisteredObject' functionObject.
Executes application functionObjects to post-process existing results.
If the "dict" argument is specified the functionObjectList is constructed
from that dictionary otherwise the functionObjectList is constructed from
the "functions" sub-dictionary of "system/controlDict"
Multiple time-steps may be processed and the standard utility time
controls are provided.
This functionality is equivalent to execFlowFunctionObjects but in a
more efficient and general manner and will be included in all the
OpenFOAM solvers if it proves effective and maintainable.
The command-line options available with the "-postProcess" option may be
obtained by
simpleFoam -help -postProcess
Usage: simpleFoam [OPTIONS]
options:
-case <dir> specify alternate case directory, default is the cwd
-constant include the 'constant/' dir in the times list
-dict <file> read control dictionary from specified location
-latestTime select the latest time
-newTimes select the new times
-noFunctionObjects
do not execute functionObjects
-noZero exclude the '0/' dir from the times list, has precedence
over the -withZero option
-parallel run in parallel
-postProcess Execute functionObjects only
-region <name> specify alternative mesh region
-roots <(dir1 .. dirN)>
slave root directories for distributed running
-time <ranges> comma-separated time ranges - eg, ':10,20,40:70,1000:'
-srcDoc display source code in browser
-doc display application documentation in browser
-help print the usage
Henry G. Weller
CFD Direct Ltd.
These new names are more consistent and logical because:
primitiveField():
primitiveFieldRef():
Provides low-level access to the Field<Type> (primitive field)
without dimension or mesh-consistency checking. This should only be
used in the low-level functions where dimensional consistency is
ensured by careful programming and computational efficiency is
paramount.
internalField():
internalFieldRef():
Provides access to the DimensionedField<Type, GeoMesh> of values on
the internal mesh-type for which the GeometricField is defined and
supports dimension and checking and mesh-consistency checking.
e.g. (fvc::interpolate(HbyA) & mesh.Sf()) -> fvc::flux(HbyA)
This removes the need to create an intermediate face-vector field when
computing fluxes which is more efficient, reduces the peak storage and
improved cache coherency in addition to providing a simpler and cleaner
API.
The deprecated non-const tmp functionality is now on the compiler switch
NON_CONST_TMP which can be enabled by adding -DNON_CONST_TMP to EXE_INC
in the Make/options file. However, it is recommended to upgrade all
code to the new safer tmp by using the '.ref()' member function rather
than the non-const '()' dereference operator when non-const access to
the temporary object is required.
Please report any problems on Mantis.
Henry G. Weller
CFD Direct.
The boundary conditions of HbyA are now constrained by the new "constrainHbyA"
function which applies the velocity boundary values for patches for which the
velocity cannot be modified by assignment and pressure extrapolation is
not specified via the new
"fixedFluxExtrapolatedPressureFvPatchScalarField".
The new function "constrainPressure" sets the pressure gradient
appropriately for "fixedFluxPressureFvPatchScalarField" and
"fixedFluxExtrapolatedPressureFvPatchScalarField" boundary conditions to
ensure the evaluated flux corresponds to the known velocity values at
the boundary.
The "fixedFluxPressureFvPatchScalarField" boundary condition operates
exactly as before, ensuring the correct flux at fixed-flux boundaries by
compensating for the body forces (gravity in particular) with the
pressure gradient.
The new "fixedFluxExtrapolatedPressureFvPatchScalarField" boundary
condition may be used for cases with or without body-forces to set the
pressure gradient to compensate not only for the body-force but also the
extrapolated "HbyA" which provides a second-order boundary condition for
pressure. This is useful for a range a problems including impinging
flow, extrapolated inlet conditions with body-forces or for highly
viscous flows, pressure-induced separation etc. To test this boundary
condition at walls in the motorBike tutorial case set
lowerWall
{
type fixedFluxExtrapolatedPressure;
}
motorBikeGroup
{
type fixedFluxExtrapolatedPressure;
}
Currently the new extrapolated pressure boundary condition is supported
for all incompressible and sub-sonic compressible solvers except those
providing implicit and tensorial porosity support. The approach will be
extended to cover these solvers and options in the future.
Note: the extrapolated pressure boundary condition is experimental and
requires further testing to assess the range of applicability,
stability, accuracy etc.
Henry G. Weller
CFD Direct Ltd.
fvOptions are transferred to the database on construction using
fv::options::New which returns a reference. The same function can be
use for construction and lookup so that fvOptions are now entirely
demand-driven.
The abstract base-classes for fvOptions now reside in the finiteVolume
library simplifying compilation and linkage. The concrete
implementations of fvOptions are still in the single monolithic
fvOptions library but in the future this will be separated into smaller
libraries based on application area which may be linked at run-time in
the same manner as functionObjects.
so that the specification of the name and dimensions are optional in property dictionaries.
Update tutorials so that the name of the dimensionedScalar property is
no longer duplicated but optional dimensions are still provided and are
checked on read.
Added calls to setFluxRequired for p in all incompressible solvers which
avoids the need to add fluxRequired entries in fvSchemes dictionary.
Will add calls to setFluxRequired to the rest of the solvers.
Select using the optional
consistent true;
setting in the PIMPLE dictionary of fvSolution.
This option is generally only beneficial for cases run in PIMPLE-mode
with a large maximum Courant number.
to support laminar simulations in the new framework.
Unfortunately this allows LES models to be instantiated although they
are not compatible with steady-state simulations.
fvOptions does not have the appropriate structure to support MRF as it
is based on option selection by user-specified fields whereas MRF MUST
be applied to all velocity fields in the particular solver. A
consequence of the particular design choices in fvOptions made it
difficult to support MRF for multiphase and it is easier to support
frame-related and field related options separately.
Currently the MRF functionality provided supports only rotations but
the structure will be generalized to support other frame motions
including linear acceleration, SRF rotation and 6DoF which will be
run-time selectable.
SIMPLEC (SIMPLE-consistent) is selected by setting "consistent" option true/yes:
SIMPLE
{
nNonOrthogonalCorrectors 0;
consistent yes;
}
which relaxes the pressure in a "consistent" manner and additional
relaxation of the pressure is not generally necessary. In addition
convergence of the p-U system is better and reliable with less
aggressive relaxation of the momentum equation, e.g. for the motorbike
tutorial:
relaxationFactors
{
equations
{
U 0.9;
k 0.7;
omega 0.7;
}
}
The cost per iteration is marginally higher but the convergence rate is
better so the number of iterations can be reduced.
The SIMPLEC algorithm also provides benefit for cases with large
body-forces, e.g. SRF, see tutorials/incompressible/SRFSimpleFoam/mixer
and feature request http://www.openfoam.org/mantisbt/view.php?id=1714
Disadvantage is that the BC values have to be specified in terms of hU
rather than U. The alternative would be to add complex code to map h
and U BCs into the equivalent for hU.
Resolves bug-report http://www.openfoam.org/mantisbt/view.php?id=1566
The old separate incompressible and compressible libraries have been removed.
Most of the commonly used RANS and LES models have been upgraded to the
new framework but there are a few missing which will be added over the
next few days, in particular the realizable k-epsilon model. Some of
the less common incompressible RANS models have been introduced into the
new library instantiated for incompressible flow only. If they prove to
be generally useful they can be templated for compressible and
multiphase application.
The Spalart-Allmaras DDES and IDDES models have been thoroughly
debugged, removing serious errors concerning the use of S rather than
Omega.
The compressible instances of the models have been augmented by a simple
backward-compatible eddyDiffusivity model for thermal transport based on
alphat and alphaEff. This will be replaced with a separate run-time
selectable thermal transport model framework in a few weeks.
For simplicity and ease of maintenance and further development the
turbulent transport and wall modeling is based on nut/nuEff rather than
mut/muEff for compressible models so that all forms of turbulence models
can use the same wall-functions and other BCs.
All turbulence model selection made in the constant/turbulenceProperties
dictionary with RAS and LES as sub-dictionaries rather than in separate
files which added huge complexity for multiphase.
All tutorials have been updated so study the changes and update your own
cases by comparison with similar cases provided.
Sorry for the inconvenience in the break in backward-compatibility but
this update to the turbulence modeling is an essential step in the
future of OpenFOAM to allow more models to be added and maintained for a
wider range of cases and physics. Over the next weeks and months more
turbulence models will be added of single and multiphase flow, more
additional sub-models and further development and testing of existing
models. I hope this brings benefits to all OpenFOAM users.
Henry G. Weller