so that the specification of the name and dimensions are optional in property dictionaries.
Update tutorials so that the name of the dimensionedScalar property is
no longer duplicated but optional dimensions are still provided and are
checked on read.
by introducing rational base-classes rather than using the hideous
'switch' statement. Further rationalization of the cell-selection
mechanism will be implemented via an appropriate class hierarchy to
replace the remaining 'switch' statement.
Mesh-motion is currently handled very inefficiently for cellSets and not
at all for inter-region coupling. The former will be improved when the
cell-selection classes are written and the latter by making the
meshToMesh class a MeshObject after it has been corrected for mapFields.
fvOptions does not have the appropriate structure to support MRF as it
is based on option selection by user-specified fields whereas MRF MUST
be applied to all velocity fields in the particular solver. A
consequence of the particular design choices in fvOptions made it
difficult to support MRF for multiphase and it is easier to support
frame-related and field related options separately.
Currently the MRF functionality provided supports only rotations but
the structure will be generalized to support other frame motions
including linear acceleration, SRF rotation and 6DoF which will be
run-time selectable.
nLimiterIter: Number of iterations during limiter construction
3 (default) is sufficient for 3D simulations with a Courant number 0.5 or so
For larger Courant numbers larger values may be needed but this is
only relevant for IMULES and CMULES
smoothLimiter: Coefficient to smooth the limiter to avoid "diamond"
staggering patters seen in regions of low particle phase-fraction in
fluidised-bed simulations.
The default is 0 as it is not needed for all simulations.
A value of 0.1 is appropriate for fluidised-bed simulations.
The useful range is 0 -> 0.5.
Values larger than 0.5 may cause excessive smearing of the solution.
For multi-region cases the default location of blockMeshDict is now system/<region name>
If the blockMeshDict is not found in system then the constant directory
is also checked providing backward-compatibility