The modes of operation are set by the dimensions of the pressure field
to which this boundary condition is applied, the \c psi entry and the value
of \c gamma:
\table
Mode | dimensions | psi | gamma
incompressible subsonic | p/rho | |
compressible subsonic | p | none |
compressible transonic | p | psi | 1
compressible supersonic | p | psi | > 1
\endtable
For most applications the totalPressure boundary condition now only
requires p0 to be specified e.g.
outlet
{
type totalPressure;
p0 uniform 1e5;
}