In most boundary conditions, fvOptions etc. required and optional fields to be looked-up from the objectRegistry are selected by setting the keyword corresponding to the standard field name in the BC etc. to the appropriate name in the objectRegistry. Usually a default is provided with sets the field name to the keyword name, e.g. in the totalPressureFvPatchScalarField the velocity is selected by setting the keyword 'U' to the appropriate name which defaults to 'U': Property | Description | Required | Default value U | velocity field name | no | U phi | flux field name | no | phi . . . However, in some BCs and functionObjects and many fvOptions another convention is used in which the field name keyword is appended by 'Name' e.g. Property | Description | Required | Default value pName | pressure field name | no | p UName | velocity field name | no | U This difference in convention is unnecessary and confusing, hinders code and dictionary reuse and complicates code maintenance. In this commit the appended 'Name' is removed from the field selection keywords standardizing OpenFOAM on the first convention above.
173 lines
3.9 KiB
C++
173 lines
3.9 KiB
C++
/*--------------------------------*- C++ -*----------------------------------*\
|
|
| ========= | |
|
|
| \\ / F ield | OpenFOAM: The Open Source CFD Toolbox |
|
|
| \\ / O peration | Version: dev |
|
|
| \\ / A nd | Web: www.OpenFOAM.org |
|
|
| \\/ M anipulation | |
|
|
\*---------------------------------------------------------------------------*/
|
|
FoamFile
|
|
{
|
|
version 2.0;
|
|
format ascii;
|
|
class dictionary;
|
|
object changeDictionaryDict;
|
|
}
|
|
// * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * //
|
|
|
|
dictionaryReplacement
|
|
{
|
|
U
|
|
{
|
|
internalField uniform (0.001 0 0);
|
|
|
|
boundaryField
|
|
{
|
|
minX
|
|
{
|
|
type fixedValue;
|
|
value uniform (0.001 0 0);
|
|
}
|
|
|
|
maxX
|
|
{
|
|
type inletOutlet;
|
|
inletValue uniform (0 0 0);
|
|
}
|
|
|
|
".*"
|
|
{
|
|
type fixedValue;
|
|
value uniform (0 0 0);
|
|
}
|
|
}
|
|
}
|
|
|
|
T
|
|
{
|
|
internalField uniform 300;
|
|
|
|
boundaryField
|
|
{
|
|
minX
|
|
{
|
|
type fixedValue;
|
|
value uniform 300;
|
|
}
|
|
|
|
maxX
|
|
{
|
|
type inletOutlet;
|
|
inletValue uniform 300;
|
|
}
|
|
|
|
".*"
|
|
{
|
|
type zeroGradient;
|
|
value uniform 300;
|
|
}
|
|
|
|
"bottomWater_to_.*"
|
|
{
|
|
type compressible::turbulentTemperatureCoupledBaffleMixed;
|
|
Tnbr T;
|
|
kappaMethod fluidThermo;
|
|
value uniform 300;
|
|
}
|
|
}
|
|
}
|
|
|
|
epsilon
|
|
{
|
|
internalField uniform 0.01;
|
|
|
|
boundaryField
|
|
{
|
|
minX
|
|
{
|
|
type fixedValue;
|
|
value uniform 0.01;
|
|
}
|
|
|
|
maxX
|
|
{
|
|
type inletOutlet;
|
|
inletValue uniform 0.01;
|
|
}
|
|
|
|
".*"
|
|
{
|
|
type epsilonWallFunction;
|
|
value uniform 0.01;
|
|
}
|
|
}
|
|
}
|
|
|
|
k
|
|
{
|
|
internalField uniform 0.1;
|
|
|
|
boundaryField
|
|
{
|
|
minX
|
|
{
|
|
type inletOutlet;
|
|
inletValue uniform 0.1;
|
|
}
|
|
|
|
maxX
|
|
{
|
|
type zeroGradient;
|
|
value uniform 0.1;
|
|
}
|
|
|
|
".*"
|
|
{
|
|
type kqRWallFunction;
|
|
value uniform 0.1;
|
|
}
|
|
}
|
|
}
|
|
|
|
p_rgh
|
|
{
|
|
internalField uniform 0;
|
|
|
|
boundaryField
|
|
{
|
|
minX
|
|
{
|
|
type zeroGradient;
|
|
value uniform 0;
|
|
}
|
|
|
|
maxX
|
|
{
|
|
type fixedValue;
|
|
value uniform 0;
|
|
}
|
|
|
|
".*"
|
|
{
|
|
type fixedFluxPressure;
|
|
value uniform 0;
|
|
}
|
|
}
|
|
}
|
|
|
|
p
|
|
{
|
|
internalField uniform 0;
|
|
|
|
boundaryField
|
|
{
|
|
".*"
|
|
{
|
|
type calculated;
|
|
value uniform 0;
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
// ************************************************************************* //
|