- enumerated values are (points | topology) which can be optionally
specified in the blockMeshDict. Default is 'topology'.
If the command-line option `blockMesh -merge-points` is specified,
this has absolute priority over any blockMeshDict entry.
STYLE: changed blockMesh "-blockTopology" option to "-write-obj"
- this is more specific to what it does. Potentially wish to add a
"-write-vtk" option in the future.
TUT: adjust tutorials to use preferred or necessary merge strategies:
* channel395DFSEM - topology
* nozzleFlow2D - points
* pipeCyclic - points