ENH: Several modifycations to avoid erroneuos rays to be shot
from wrong faces.
ENH: Updating tutorials and avoiding registration of the
coarse singleCellFvMesh
Adding solarLoad tutorial case simpleCarSolarPanel
ENH: Changes needed for the merge
Adding reflecting fluxes to Solar load radiation model.
Adding functionality to the boundary radiation models and new
place holder for basic wall types such as transparent, opaqueDiffusive,
opaqueReflective,etc.
Changing radiation wall models to run time selectable.
Adding multi-band capabilities to VF model and improving the set up
for using solar loads in VF and fvDOM radiation models.
- check if the first argument corresponds to an OpenFOAM value for
'true' (as per Switch).
True == 't', 'y', 'true', 'yes', 'on'. Everything else is not true.
- when the first argument is '-dict', it initializes the value
with a query via foamDictionary.
Eg,
isTrue -dict mydict -entry parallel
==> value=$(foamDictionary mydict -entry parallel -value)
isTrue $value
a missing entry is silently treated as false.
ENH: add getNumberOfPatchFaces function in RunFunctions
- simple extraction of nFaces from boundary file for given patch/region
- helps reduce clutter in the topoSetDict files.
Caveats when using this.
The older specification styles using "name" will conflict with the
set name. Eg,
{
name f0
type faceSet;
action add;
source patchToFace;
sourceInfo
{
name inlet;
}
}
would flattened to the following
{
name f0
type faceSet;
action add;
source patchToFace;
name inlet;
}
which overwrites the "name" used for the faceSet.
The solution is to use the updated syntax:
{
name f0
type faceSet;
action add;
source patchToFace;
patch inlet;
}
Previously the coordinate system functionality was split between
coordinateSystem and coordinateRotation. The coordinateRotation stored
the rotation tensor and handled all tensor transformations.
The functionality has now been revised and consolidated into the
coordinateSystem classes. The sole purpose of coordinateRotation
is now just to provide a selectable mechanism of how to define the
rotation tensor (eg, axis-angle, euler angles, local axes) for user
input, but after providing the appropriate rotation tensor it has
no further influence on the transformations.
--
The coordinateSystem class now contains an origin and a base rotation
tensor directly and various transformation methods.
- The origin represents the "shift" for a local coordinate system.
- The base rotation tensor represents the "tilt" or orientation
of the local coordinate system in general (eg, for mapping
positions), but may require position-dependent tensors when
transforming vectors and tensors.
For some coordinate systems (currently the cylindrical coordinate system),
the rotation tensor required for rotating a vector or tensor is
position-dependent.
The new coordinateSystem and its derivates (cartesian, cylindrical,
indirect) now provide a uniform() method to define if the rotation
tensor is position dependent/independent.
The coordinateSystem transform and invTransform methods are now
available in two-parameter forms for obtaining position-dependent
rotation tensors. Eg,
... = cs.transform(globalPt, someVector);
In some cases it can be useful to use query uniform() to avoid
storage of redundant values.
if (cs.uniform())
{
vector xx = cs.transform(someVector);
}
else
{
List<vector> xx = cs.transform(manyPoints, someVector);
}
Support transform/invTransform for common data types:
(scalar, vector, sphericalTensor, symmTensor, tensor).
====================
Breaking Changes
====================
- These changes to coordinate systems and rotations may represent
a breaking change for existing user coding.
- Relocating the rotation tensor into coordinateSystem itself means
that the coordinate system 'R()' method now returns the rotation
directly instead of the coordinateRotation. The method name 'R()'
was chosen for consistency with other low-level entities (eg,
quaternion).
The following changes will be needed in coding:
Old: tensor rot = cs.R().R();
New: tensor rot = cs.R();
Old: cs.R().transform(...);
New: cs.transform(...);
Accessing the runTime selectable coordinateRotation
has moved to the rotation() method:
Old: Info<< "Rotation input: " << cs.R() << nl;
New: Info<< "Rotation input: " << cs.rotation() << nl;
- Naming consistency changes may also cause code to break.
Old: transformVector()
New: transformPrincipal()
The old method name transformTensor() now simply becomes transform().
====================
New methods
====================
For operations requiring caching of the coordinate rotations, the
'R()' method can be used with multiple input points:
tensorField rots(cs.R(somePoints));
and later
Foam::transformList(rots, someVectors);
The rotation() method can also be used to change the rotation tensor
via a new coordinateRotation definition (issue #879).
The new methods transformPoint/invTransformPoint provide
transformations with an origin offset using Cartesian for both local
and global points. These can be used to determine the local position
based on the origin/rotation without interpreting it as a r-theta-z
value, for example.
================
Input format
================
- Streamline dictionary input requirements
* The default type is cartesian.
* The default rotation type is the commonly used axes rotation
specification (with e1/e2/3), which is assumed if the 'rotation'
sub-dictionary does not exist.
Example,
Compact specification:
coordinateSystem
{
origin (0 0 0);
e2 (0 1 0);
e3 (0.5 0 0.866025);
}
Full specification (also accepts the longer 'coordinateRotation'
sub-dictionary name):
coordinateSystem
{
type cartesian;
origin (0 0 0);
rotation
{
type axes;
e2 (0 1 0);
e3 (0.5 0 0.866025);
}
}
This simplifies the input for many cases.
- Additional rotation specification 'none' (an identity rotation):
coordinateSystem
{
origin (0 0 0);
rotation { type none; }
}
- Additional rotation specification 'axisAngle', which is similar
to the -rotate-angle option for transforming points (issue #660).
For some cases this can be more intuitive.
For example,
rotation
{
type axisAngle;
axis (0 1 0);
angle 30;
}
vs.
rotation
{
type axes;
e2 (0 1 0);
e3 (0.5 0 0.866025);
}
- shorter names (or older longer names) for the coordinate rotation
specification.
euler EulerRotation
starcd STARCDRotation
axes axesRotation
================
Coding Style
================
- use Foam::coordSystem namespace for categories of coordinate systems
(cartesian, cylindrical, indirect). This reduces potential name
clashes and makes a clearer declaration. Eg,
coordSystem::cartesian csys_;
The older names (eg, cartesianCS, etc) remain available via typedefs.
- added coordinateRotations namespace for better organization and
reduce potential name clashes.
Support the following expansions when they occur at the start of a
string:
Short-form Equivalent
========= ===========
<etc>/ ~OpenFOAM/ (as per foamEtcFile)
<case>/ $FOAM_CASE/
<constant>/ $FOAM_CASE/constant/
<system>/ $FOAM_CASE/system/
These can be used in fileName expansions to improve clarity and reduce
some typing
"<constant>/reactions" vs "$FOAM_CASE/constant/reactions"
Within decomposeParDict, it is now possible to specify a different
decomposition method, methods coefficients or number of subdomains
for each region individually.
The top-level numberOfSubdomains remains mandatory, since this
specifies the number of domains for the entire simulation.
The individual regions may use the same number or fewer domains.
Any optional method coefficients can be specified in a general
"coeffs" entry or a method-specific one, eg "metisCoeffs".
For multiLevel, only the method-specific "multiLevelCoeffs" dictionary
is used, and is also mandatory.
----
ENH: shortcut specification for multiLevel.
In addition to the longer dictionary form, it is also possible to
use a shorter notation for multiLevel decomposition when the same
decomposition method applies to each level.
- although this has been supported for many years, the tutorials
continued to use "convertToMeters" entry, which is specific to blockMesh.
The "scale" is more consistent with other dictionaries.
ENH:
- ignore "scale 0;" (treat as no scaling) for blockMeshDict,
consistent with use elsewhere.
- Use on/off vs longer compressed/uncompressed.
For consistency, replaced yes/no with on/off.
- Avoid the combination of binary/compressed,
which is disallowed and provokes a warning anyhow
Evolves an electrical potential equation
\f[
\grad \left( \sigma \grad V \right)
\f]
where \f$ V \f$ is electrical potential and \f$\sigma\f$ is the
electrical current
To provide a Joule heating contribution according to:
Differential form of Joule heating - power per unit volume:
\f[
\frac{d(P)}{d(V)} = J \cdot E
\f]
where \f$ J \f$ is the current density and \f$ E \f$ the electric
field.
If no magnetic field is present:
\f[
J = \sigma E
\f]
The electric field given by
\f[
E = \grad V
\f]
Therefore:
\f[
\frac{d(P)}{d(V)} = J \cdot E
= (sigma E) \cdot E
= (sigma \grad V) \cdot \grad V
\f]
Usage
Isotropic (scalar) electrical conductivity
\verbatim
jouleHeatingSourceCoeffs
{
anisotropicElectricalConductivity no;
// Optionally specify the conductivity as a function of
// temperature
// Note: if not supplied, this will be read from the time
// directory
sigma table
(
(273 1e5)
(1000 1e5)
);
}
\endverbatim
Anisotropic (vectorial) electrical conductivity
jouleHeatingSourceCoeffs
{
anisotropicElectricalConductivity yes;
coordinateSystem
{
type cartesian;
origin (0 0 0);
coordinateRotation
{
type axesRotation;
e1 (1 0 0);
e3 (0 0 1);
}
}
// Optionally specify sigma as a function of temperature
//sigma (31900 63800 127600);
//
//sigma table
//(
// (0 (0 0 0))
// (1000 (127600 127600 127600))
//);
}
Where:
\table
Property | Description | Required | Default
value
T | Name of temperature field | no | T
sigma | Electrical conductivity as a function of
temperature |no|
anisotropicElectricalConductivity | Anisotropic flag | yes |
\endtable
The electrical conductivity can be specified using either:
- If the \c sigma entry is present the electrical conductivity is
specified
as a function of temperature using a Function1 type
- If not present the sigma field will be read from file
- If the anisotropicElectricalConductivity flag is set to 'true',
sigma
should be specified as a vector quantity
For example the actuationDiskSource fvOption may now be specified
disk1
{
type actuationDiskSource;
fields (U);
selectionMode cellSet;
cellSet actuationDisk1;
diskDir (1 0 0); // Orientation of the disk
Cp 0.386;
Ct 0.58;
diskArea 40;
upstreamPoint (581849 4785810 1065);
}
rather than
disk1
{
type actuationDiskSource;
active on;
actuationDiskSourceCoeffs
{
fields (U);
selectionMode cellSet;
cellSet actuationDisk1;
diskDir (1 0 0); // Orientation of the disk
Cp 0.386;
Ct 0.58;
diskArea 40;
upstreamPoint (581849 4785810 1065);
}
}
but this form is supported for backward compatibility.
The standard naming convention for heat flux is "q" and this is used for the
conductive and convective heat fluxes is OpenFOAM. The use of "Qr" for
radiative heat flux is an anomaly which causes confusion, particularly for
boundary conditions in which "Q" is used to denote power in Watts. The name of
the radiative heat flux has now been corrected to "qr" and all models, boundary
conditions and tutorials updated.
The fundamental properties provided by the specie class hierarchy were
mole-based, i.e. provide the properties per mole whereas the fundamental
properties provided by the liquidProperties and solidProperties classes are
mass-based, i.e. per unit mass. This inconsistency made it impossible to
instantiate the thermodynamics packages (rhoThermo, psiThermo) used by the FV
transport solvers on liquidProperties. In order to combine VoF with film and/or
Lagrangian models it is essential that the physical propertied of the three
representations of the liquid are consistent which means that it is necessary to
instantiate the thermodynamics packages on liquidProperties. This requires
either liquidProperties to be rewritten mole-based or the specie classes to be
rewritten mass-based. Given that most of OpenFOAM solvers operate
mass-based (solve for mass-fractions and provide mass-fractions to sub-models it
is more consistent and efficient if the low-level thermodynamics is also
mass-based.
This commit includes all of the changes necessary for all of the thermodynamics
in OpenFOAM to operate mass-based and supports the instantiation of
thermodynamics packages on liquidProperties.
Note that most users, developers and contributors to OpenFOAM will not notice
any difference in the operation of the code except that the confusing
nMoles 1;
entries in the thermophysicalProperties files are no longer needed or used and
have been removed in this commet. The only substantial change to the internals
is that species thermodynamics are now "mixed" with mass rather than mole
fractions. This is more convenient except for defining reaction equilibrium
thermodynamics for which the molar rather than mass composition is usually know.
The consequence of this can be seen in the adiabaticFlameT, equilibriumCO and
equilibriumFlameT utilities in which the species thermodynamics are
pre-multiplied by their molecular mass to effectively convert them to mole-basis
to simplify the definition of the reaction equilibrium thermodynamics, e.g. in
equilibriumCO
// Reactants (mole-based)
thermo FUEL(thermoData.subDict(fuelName)); FUEL *= FUEL.W();
// Oxidant (mole-based)
thermo O2(thermoData.subDict("O2")); O2 *= O2.W();
thermo N2(thermoData.subDict("N2")); N2 *= N2.W();
// Intermediates (mole-based)
thermo H2(thermoData.subDict("H2")); H2 *= H2.W();
// Products (mole-based)
thermo CO2(thermoData.subDict("CO2")); CO2 *= CO2.W();
thermo H2O(thermoData.subDict("H2O")); H2O *= H2O.W();
thermo CO(thermoData.subDict("CO")); CO *= CO.W();
// Product dissociation reactions
thermo CO2BreakUp
(
CO2 == CO + 0.5*O2
);
thermo H2OBreakUp
(
H2O == H2 + 0.5*O2
);
Please report any problems with this substantial but necessary rewrite of the
thermodynamic at https://bugs.openfoam.org
Henry G. Weller
CFD Direct Ltd.
using a run-time selectable preconditioner
References:
Van der Vorst, H. A. (1992).
Bi-CGSTAB: A fast and smoothly converging variant of Bi-CG
for the solution of nonsymmetric linear systems.
SIAM Journal on scientific and Statistical Computing, 13(2), 631-644.
Barrett, R., Berry, M. W., Chan, T. F., Demmel, J., Donato, J.,
Dongarra, J., Eijkhout, V., Pozo, R., Romine, C. & Van der Vorst, H.
(1994).
Templates for the solution of linear systems:
building blocks for iterative methods
(Vol. 43). Siam.
See also: https://en.wikipedia.org/wiki/Biconjugate_gradient_stabilized_method
Tests have shown that PBiCGStab with the DILU preconditioner is more
robust, reliable and shows faster convergence (~2x) than PBiCG with
DILU, in particular in parallel where PBiCG occasionally diverges.
This remarkable improvement over PBiCG prompted the update of all
tutorial cases currently using PBiCG to use PBiCGStab instead. If any
issues arise with this update please report on Mantis: http://bugs.openfoam.org
Added the option '-subDict' to specify a sub-dictionary if multiple
replacement sets are present in the same file. This also provides
backward compatibility by setting '-subDict dictionaryReplacement'
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry. Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':
Property | Description | Required | Default value
U | velocity field name | no | U
phi | flux field name | no | phi
.
.
.
However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.
Property | Description | Required | Default value
pName | pressure field name | no | p
UName | velocity field name | no | U
This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance. In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.