- new '-ascii' option to write in ASCII format instead of the
controlDict setting. This can be useful when generating fields that
should be parsed with other tools, or for visual inspection.
- correct mismatch of option names and lookups
- can use either command-line option "-load-fields" or dictionary
entry "readFields" to specify field names to be preloaded.
Essentially the same functionality as with a readFields function
object but with a lot less typing.
- tutorial examples provided by Ryan Danks <ryan.danks@rwdi.com>
illustrate using setExpr* utilities to calculate a quantity
as a post-processing step.
Please refer to the header file documentation for complete set of details.
ENH: add new fvOptions for ABL modelling
- atmAmbientTurbSource
- atmBuoyancyTurbSource
- atmCoriolisUSource
- atmLengthScaleTurbSource
- atmPlantCanopyTurbSource
- atmPlantCanopyUSource
- atmPlantCanopyTSource
- atmNutSource
ENH: add new boundary conditions for ABL modelling
with PatchFunction1 and TimeFunction1 support
- atmAlphatkWallFunction
- atmEpsilonWallFunction
- atmNutkWallFunction
- atmNutUWallFunction
- atmNutWallFunction
- atmOmegaWallFunction
- atmTurbulentHeatFluxTemperature
STYLE: change names of nutkAtmRoughWallFunction -> atmNutkWallFunction by
ensuring the bitwise backward compatibility
ENH: add new variable-scaling force computation method to actuationDiskSource
ENH: review actuationDiskSource and radialActuationDiskSource
ENH: add new function object, ObukhovLength
ENH: add new ABL tutorials/verifications
- verificationAndValidation/atmosphericModels/atmFlatTerrain
- verification with the Leipzig field experiment
- illustration of precursor/successor field mapping
- verificationAndValidation/atmosphericModels/atmForestStability
- verification with the Sweden field experiment
- update incompressible/simpleFoam/turbineSiting
ENH: add generalised log-law type ground-normal inflow boundary conditions for
wind velocity and turbulence quantities for homogeneous, two-dimensional,
dry-air, equilibrium and neutral atmospheric boundary layer (ABL) modelling
ENH: remove `zGround` entry, which is now automatically computed
ENH: add `displacement height` entry, `d`
ENH: add generalised atmBoundaryLayerInletOmega boundary condition
ENH: add a verification case for atmBoundaryLayerInlet BCs
DOC: improve atmBoundaryLayerInlet header documentation
BUG: fix value-entry behaviour in atmBoundaryLayerInlet (fixes#1578)
Without this change:
- for serial-parallel computations, if `value` entry is available in
an `atmBoundaryLayerInlet` BC, the theoretical ABL profile expressions
are not computed, and the `value` entry content is used as a profile data
- for parallel computations, if `value` entry is not available, `decomposePar`
could not be executed.
With this change:
- assuming `value` entry is always be present, the use of `value` entry for
the ABL profile specification is determined by a flag `initABL`
- the default value of the optional flag `initABL` is `true`, but whenever
`initABL=true` is executed, `initABL` is overwritten as `false` for the
subsequent runs, so that `value` entry can be safely used.
Thanks Per Jørgensen for the bug report.
BUG: ensure atmBoundaryInlet conditions are Galilean-invariant (fixes#1692)
Related references:
The ground-normal profile expressions (tag:RH):
Richards, P. J., & Hoxey, R. P. (1993).
Appropriate boundary conditions for computational wind
engineering models using the k-ε turbulence model.
In Computational Wind Engineering 1 (pp. 145-153).
DOI:10.1016/B978-0-444-81688-7.50018-8
Modifications to preserve the profiles downstream (tag:HW):
Hargreaves, D. M., & Wright, N. G. (2007).
On the use of the k–ε model in commercial CFD software
to model the neutral atmospheric boundary layer.
Journal of wind engineering and
industrial aerodynamics, 95(5), 355-369.
DOI:10.1016/j.jweia.2006.08.002
Expression generalisations to allow height
variation for turbulence quantities (tag:YGCJ):
Yang, Y., Gu, M., Chen, S., & Jin, X. (2009).
New inflow boundary conditions for modelling the neutral equilibrium
atmospheric boundary layer in computational wind engineering.
J. of Wind Engineering and Industrial Aerodynamics, 97(2), 88-95.
DOI:10.1016/j.jweia.2008.12.001
The generalised ground-normal profile expression for omega (tag:YGJ):
Yang, Y., Gu, M., & Jin, X., (2009).
New inflow boundary conditions for modelling the
neutral equilibrium atmospheric boundary layer in SST k-ω model.
In: The Seventh Asia-Pacific Conference on Wind Engineering,
November 8-12, Taipei, Taiwan.
Reproduced benchmark:
Rectangular prism shown in FIG 1 of
Hargreaves, D. M., & Wright, N. G. (2007).
On the use of the k–ε model in commercial CFD software
to model the neutral atmospheric boundary layer.
Journal of wind engineering and
industrial aerodynamics, 95(5), 355-369.
DOI:10.1016/j.jweia.2006.08.002
Benchmark data:
HW, 2007 FIG 6
TUT: update simpleFoam/turbineSiting tutorial accordingly
- helps reduce clutter in the topoSetDict files.
Caveats when using this.
The older specification styles using "name" will conflict with the
set name. Eg,
{
name f0
type faceSet;
action add;
source patchToFace;
sourceInfo
{
name inlet;
}
}
would flattened to the following
{
name f0
type faceSet;
action add;
source patchToFace;
name inlet;
}
which overwrites the "name" used for the faceSet.
The solution is to use the updated syntax:
{
name f0
type faceSet;
action add;
source patchToFace;
patch inlet;
}
- improve doxygen entries for searchable surfaces.
- support selection of searchable surfaces with shorter names.
Eg,
type box | cylinder | ...;
vs type searchableBox | searchableCylinder | ...;
Within decomposeParDict, it is now possible to specify a different
decomposition method, methods coefficients or number of subdomains
for each region individually.
The top-level numberOfSubdomains remains mandatory, since this
specifies the number of domains for the entire simulation.
The individual regions may use the same number or fewer domains.
Any optional method coefficients can be specified in a general
"coeffs" entry or a method-specific one, eg "metisCoeffs".
For multiLevel, only the method-specific "multiLevelCoeffs" dictionary
is used, and is also mandatory.
----
ENH: shortcut specification for multiLevel.
In addition to the longer dictionary form, it is also possible to
use a shorter notation for multiLevel decomposition when the same
decomposition method applies to each level.
- although this has been supported for many years, the tutorials
continued to use "convertToMeters" entry, which is specific to blockMesh.
The "scale" is more consistent with other dictionaries.
ENH:
- ignore "scale 0;" (treat as no scaling) for blockMeshDict,
consistent with use elsewhere.
- Use on/off vs longer compressed/uncompressed.
For consistency, replaced yes/no with on/off.
- Avoid the combination of binary/compressed,
which is disallowed and provokes a warning anyhow
For example the actuationDiskSource fvOption may now be specified
disk1
{
type actuationDiskSource;
fields (U);
selectionMode cellSet;
cellSet actuationDisk1;
diskDir (1 0 0); // Orientation of the disk
Cp 0.386;
Ct 0.58;
diskArea 40;
upstreamPoint (581849 4785810 1065);
}
rather than
disk1
{
type actuationDiskSource;
active on;
actuationDiskSourceCoeffs
{
fields (U);
selectionMode cellSet;
cellSet actuationDisk1;
diskDir (1 0 0); // Orientation of the disk
Cp 0.386;
Ct 0.58;
diskArea 40;
upstreamPoint (581849 4785810 1065);
}
}
but this form is supported for backward compatibility.
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry. Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':
Property | Description | Required | Default value
U | velocity field name | no | U
phi | flux field name | no | phi
.
.
.
However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.
Property | Description | Required | Default value
pName | pressure field name | no | p
UName | velocity field name | no | U
This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance. In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
See http://www.openfoam.org/mantisbt/view.php?id=2076
- .org is the file extension for emacs org-mode as well
- .orig is more to the point (.org isn't always recognized as "original")
- .original is too long, although more consistent with the convention
of source code file naming
Update script contributed by Bruno Santos
RunFunctions: Added "isTest()" argument parsing function
tutorials: Updated Allrun scripts to propagate the "-test" option
tutorials: Removed the lower Alltest scripts and updated the Allrun to
use the "isTest()" function to handle test-specific operation
in decomposeParDict.
This default number of processors may be overridden by the new "-np"
option to runParallel which must be specified before the application
name e.g.:
runParallel -np 4 pisoFoam